Wednesday, March 14, 2007

How To Repair Macroview Mp712s 17" CRT Monitor

The complaint for this Macroview mp712s 17" monitor was no power. Once the cover was removed and power on, you could hear a soft "chip-chip" sound indicating the power trying to come out but something had caused it to shut down. The LED indicator has no light at all. Just like troubleshooting any other monitor problems, the first thing that I do was to look for any burnt marked, loose connection at cables, dry joints and burnt components. True enough, there was a crystal clear burnt marked at the center of the main board.